R+F FilterElements logo
All adsorption media
CC

Activated carbon for oil vapour & VOC removal

CC · granular activated carbon · loose fill or RF-AC cartridge

A coalescing filter stops oil aerosol – but not oil vapour. Vapour passes through any fibre element and condenses again downstream. Activated carbon closes that gap: its huge internal surface adsorbs hydrocarbons, solvent vapours and odours from the gas.

Activated carbon – Oil vapour, hydrocarbons, solvent vapours, VOC and odours.

Removes

Oil vapour, hydrocarbons, solvent vapours, VOC and odours.

Info

Not a desiccant. Little effect on light gases such as CO, CH₄ or H₂.

Typical problems

  • Residual oil vapour after the coalescing filter contaminates analysers, process gas or products
  • Odour or solvent traces in compressed air for food, pharma or laboratory use
  • Hydrocarbon traces disturb sensitive measurements or catalysts

Benefits

  • Removes vapour-phase contaminants that pass every coalescing element
  • Fine granules give good contact with the gas in a compact bed
  • Available as loose fill by the kg or pre-packed in RF-AC cartridges
  • Easy to combine with potassium permanganate in a layered bed

How it works

Activated carbon is a highly porous carbon with an internal surface of several hundred square metres per gram. Organic molecules are held on this surface by physical adsorption (van der Waals forces). Heavier, less volatile molecules adsorb best. The bed is saturated when the outlet quality rises – then the charge is replaced.

Example process train

Oil-free compressed air / process gas

Example: oil-lubricated compressor, gas used for analysers or product contact.

1 · Coalescing filter

RF-C element, grade HE (99.99 % @ 0.01 µm)

Removes liquid oil and aerosol – protects the carbon from flooding

2 · Activated carbon adsorber

RF-AC cartridge or loose-fill adsorber housing with CC

Adsorbs oil vapour, hydrocarbons and odours

3 · Particulate after-filter

RF-P element

Retains carbon fines before the point of use

Limits & notes

  • Never feed liquid oil or water to the carbon – always install a coalescing filter upstream
  • Adsorption capacity falls with rising temperature and humidity
  • Does not remove CO, CO₂, CH₄ or H₂ and is not a dryer
  • Cartridges up to 50 °C; loose fill per housing rating

Service life depends on load and operating data – figures on request are estimates.

Which medium fits your gas?

Send us gas, flow, pressure, temperature and the contaminant to remove – we propose housing, fill and pre-/after-filters.

Share this page WhatsApp LinkedIn E-mail