R+F FilterElements logo
Back to Home
Specialty Elements

Ammonia Scrubbing Elements

Phosphoric-acid-impregnated borosilicate filter elements that simultaneously capture particles and neutralise ammonia (NH₃) — protecting NOx analysers from cross-sensitivity in SCR/DeNOx emission monitoring.

RF-AW acid-washed borosilicate filter element for ammonia removal in SCR emission monitoring | R+F FilterElements
RF-AW-…-HEK / -STK

AW K-Type — Standard Temperature

PVDF-bonded acid-washed elements for ammonia removal up to 150 °C

K-type acid-washed elements use a PVDF fluorocarbon binder, making them chemically resistant and suitable for sample gas temperatures up to 150 °C (300 °F). The borosilicate glass microfibre medium is impregnated with phosphoric acid (H₃PO₄), which reacts with ammonia (NH₃) in the gas stream to form ammonium phosphate — a stable salt that remains trapped in the element. This removes ammonia slip from the sample without interfering with other gas components measured downstream.

Pressure:Per housing rating
Temp:150 °C (300 °F)
Material:Borosilicate glass / PVDF binder / Phosphoric acid
Ports:3 sizes — fits standard housings

Key Features

  • Grade HE: 99.99 % efficiency at 0.01 µm — simultaneous particle filtration and NH₃ neutralisation
  • Phosphoric acid impregnation reacts with NH₃ to form stable ammonium phosphate
  • Does not affect NOx, CO, CO₂, SO₂, or other measured gas components
  • Direct drop-in for all standard R+F housings — no system modification required
  • PVDF binder for chemical resistance in corrosive flue gas environments
  • Disposable — replace when ammonia capacity is exhausted
  • Delivery approx. 2 weeks from order
RF-AW S-type high-temperature acid-washed filter element for hot flue gas ammonia removal | R+F FilterElements
RF-AW-…-HES / -STS

AW S-Type — High Temperature

Silica-bonded acid-washed elements for flue gas up to 480 °C

S-type acid-washed elements use a silica (inorganic) binder that withstands temperatures up to 480 °C (900 °F), making them suitable for hot-side sampling points where the flue gas has not yet been cooled. Same phosphoric acid impregnation as the K-type, same ammonia neutralisation mechanism — but thermally rated for direct extraction from high-temperature ducts in power stations, cement kilns, glass furnaces, and waste incineration plants.

Pressure:Per housing rating
Temp:480 °C (900 °F)
Material:Borosilicate glass / Silica binder / Phosphoric acid
Ports:3 sizes — fits standard housings

Key Features

  • Grade HE: 99.99 % efficiency at 0.01 µm — identical NH₃ scrubbing capacity as K-type
  • Silica binder withstands 480 °C — suitable for hot extractive systems
  • Used in direct-extractive CEMS where sample is not cooled before filtration
  • Same physical dimensions and housing compatibility as K-type
  • Disposable — replace when ammonia capacity is exhausted
  • Delivery approx. 2 weeks from order

Need help selecting the right filter?

Need ammonia scrubbing elements? Contact us for sizing, pricing, and delivery.