Operating data
Medium
Nitrogen
Pressure
7 bar(g)
Flow
≥ 100 Nm³/h per filter
Material
316 stainless steel
Requested grades
1 µm and 0.3 µm

Starting point

An engineering contractor needed four nitrogen filters for a plant project: two positions with 1 µm and two with 0.3 µm, all in 316 stainless steel, at 7 bar(g) and at least 100 Nm³/h each.

Task

Meet both filtration grades with a robust stainless design and avoid different element types for a plant that will be operated far from the supplier.

How we sized it

  1. 1

    Check actual flow

    At 7 bar(g), 100 Nm³/h corresponds to roughly 13 m³/h actual flow (estimate at 15 °C). A 1″ housing handles this comfortably.

  2. 2

    Standardise the housing

    RF-H-150 in 316L with 1″ NPT for all four positions.

  3. 3

    One element for both grades

    RF-C-51230-HE separates 99.99 % at 0.01 µm and therefore exceeds both the 1 µm and the 0.3 µm requirement. Result: a single spare-part type.

Recommended configuration

RF-H-150 – Housing (all 4)
Housing (all 4)
RF-H-150

316L stainless steel, 1″ NPT.

Product details
RF-C-51230-HE – Element (all 4)
Element (all 4)
RF-C-51230-HE

Coalescing element, 99.99 % at 0.01 µm – covers 1 µm and 0.3 µm.

Product details

Limits & open points

  • Connection standardised to 1″ NPT.
  • The pressure regulator in the same package was not part of our scope.
  • Differential pressure and change interval are confirmed with the offer for the actual operating data.

Result

Four identical filters, one element type for all positions and a clear sizing basis for the contractor’s documentation.

Read more

Similar application? Send us your operating data.

Medium, pressure, temperature, flow and connection are enough for a first proposal. We answer with a configuration and a quotation.