Liquid Slugs Reaching the Analyser — Coalescer and Membrane as a Two-Stage Barrier
A coalescer removes fine aerosol continuously, but a liquid slug from a process upset can overload it within seconds. Behind the coalescer, a PTFE membrane separator acts as an absolute barrier: gas passes, liquid stays out of the analyser.
Reconocer los síntomas
- GC columns or optical sample cells flooded after a process upset
- Analyser out of service for cleaning after start-up or shut-down of the unit
- Liquid visible in the sample tubing downstream of the coalescer
- Coalescing element soaked through and differential pressure rising sharply
- Repeated failures always after the same operating event
Causas
Only one liquid stage
a coalescer is designed for aerosol, not for liquid slugs
Drain blocked, closed or too small, so separated liquid backs up in the housing
Sample tap at the bottom of the process line where liquid collects
Condensation in unheated sections of the sample line
No membrane barrier in front of liquid-sensitive analysers
Lista de comprobación de diagnóstico
- 1Take the sample from the top or side of the process line, not from the bottom
- 2Use a coalescing housing with drain: RF-H-122 (¼″ NPT, ¼″ drain, 340 bar, 200 °C) with RF-C-12057-HE
- 3Add RF-M-GMS170 behind the coalescer as absolute liquid barrier (150 bar, 100 °C)
- 4Check the drain function regularly and size the drain line for the expected liquid volume
- 5Where bulk water can arrive, put a catch pot such as RF-H-122-CP in front of the coalescer
- 6Replace a soaked coalescing element immediately; otherwise change every 3 months
Encontrar el filtro adecuado para este problema
Introduzca sus datos de operación — nuestras herramientas le guiarán al elemento y carcasa adecuados. O envíenos sus datos para una recomendación a medida.
Buscador de elementos
RecomendadoEl elemento filtrante adecuado para el medio y la operación en menos de 60 segundos — punto de partida recomendado.
Encontrar elementoUtilizar selección de carcasa
Seleccionar la carcasa adecuada — material, nivel de presión, conexiones y purga.
Seleccionar carcasaSolicitar asesoramiento
¿Prefiere atención personal? Envíe sus datos de operación y le recomendaremos la configuración adecuada.
Enviar solicitudLectura complementaria
Describa su situación — encontraremos la solución adecuada
Cada problema de filtración tiene causas específicas que requieren soluciones específicas. Envíenos sus condiciones de operación y elaboraremos una recomendación a medida.