Coalescing Filters for Methane, Biomethane and Natural Gas — DN15, 316L, PED-Compliant as Supplied

Methane lines to burners, engines, analysers or test benches need dry, aerosol-free gas. A compact two-stage filter with ½″ NPT ports covers typical DN15 lines up to 100 bar — with a closed drain, because methane must never be vented through a float drain.

Share this page WhatsApp LinkedIn E-mail

Reconocer los síntomas

  • Water or oil droplets in methane lines to burners, gas engines or test benches
  • Corrosion or deposits in pressure regulators and flow meters
  • Analysers or sensors in natural gas service drift or fail
  • Condensate in low points after compressors or outdoor sections

Causas

Water and oil aerosols from compressors, biogas upgrading or grid gas

Temperature drop along the line causes condensation

Float drains venting to atmosphere are unsuitable for flammable gas

Housings modified on site (e.g. welded flanges) lose PED conformity

Lista de comprobación de diagnóstico

  • 1Convert flow: 100 Nm³/h CH₄ at 15 bar(g) ≈ 6.8 m³/h actual — a ½″ NPT housing (RF-H-142, 316L, 100 bar ≈ 1450 psi, 200 °C) is sufficient
  • 2Two stages: RF-P-25178-ST particulate pre-filter + RF-C-25178-HE coalescer (99.99 % @ 0.01 µm); one stage for clean grid gas
  • 3Drain the ¼″ NPT bottom port manually via a valve into a closed system — no float drain venting to atmosphere
  • 4Housings are PED-compliant as supplied (2014/68/EU). Do not weld or modify them; flanged versions (e.g. DN15 PN40) are factory-supplied on request
  • 5Hazardous areas: passive metal housing, can be earthed; zone classification remains part of the plant's safety assessment
  • 6For CNG at 200–400 bar use RF-H-150HP / RF-H-150VP (1″ NPT)