Why 100 Nm³/h at 15 bar Only Needs a ½″ Filter Housing — Sizing Small Gas Filters on Actual Flow
Many gas filters are oversized because the normal flow rate is used for sizing. The filter only sees the actual (compressed) volume flow. At 15–30 bar the actual flow is 15–30 times smaller — and a compact instrumentation-size housing is often the right, cheaper choice.
Recognise the Symptoms
- A large 1″ or 2″ housing was quoted for a flow of a few Nm³/h
- The filter housing is bigger and heavier than the pipework around it
- Unclear whether the flow figure in the datasheet is normal flow (Nm³/h, SCFM) or actual flow
- Very low differential pressure — the element never loads evenly
- High cost for housings and spare elements on small laboratory or test-rig lines
Root Causes
Sizing on normal flow
the volume at 0 °C and 1.013 bar is much larger than the compressed volume flowing through the filter
Pressure ignored
actual flow ≈ normal flow × (1.013 / p_abs) × (T / 273.15); at 15 bar(g) that is roughly 1/16 of the normal flow
Port size taken from the line size instead of from the filter capacity
Missing distinction between gas and liquid load
liquid slugs need drain volume, not a larger element
Diagnostic Checklist
- 1Convert normal flow to actual flow: 100 Nm³/h CH₄ at 15 bar(g) and 20 °C ≈ 6.8 m³/h actual
- 21 Nm³/h H₂ at 20 bar(g) ≈ 55 L/h actual — a ¼″ NPT housing (RF-H-122 / RF-H-130) is sufficient
- 3270 Nm³/h at 30 bar(g) ≈ 9 m³/h actual — a ½″ NPT housing (RF-H-142, 25 × 178 mm element) is typical
- 4Above roughly 12 m³/h actual flow, or for high liquid loads, choose RF-H-150 (1″ NPT) or larger
- 5Check pressure rating with margin: 100 bar (≈ 1450 psi), 200 bar (≈ 2900 psi) or 400 bar (≈ 5800 psi) versions
- 6Use the engineering tool — it converts Nm³/h to actual flow and proposes the housing size automatically
Find the right filter for this problem
Enter your operating data and let our tools point you to the right element and housing — or send us your details for a tailored recommendation.
Element Finder
RecommendedIdentify the right filter element for your medium and duty in under 60 seconds — recommended starting point.
Find your elementUse Housing Selector
Select the matching housing — material, pressure rating, connections and drain.
Select a housingRequest a Consultation
Prefer a person? Send your operating data and we will recommend the right configuration.
Send enquiryDescribe Your Situation — We Will Find the Right Solution
Every filtration problem has specific root causes that require specific solutions. Send us your operating conditions and we will provide a tailored recommendation.