HCl or NaOH Droplets in Hydrogen — Filters with PTFE Wetted Parts for Acid and Alkaline Electrolysis
Electrolysis and chlor-alkali test rigs produce hydrogen carrying acid or alkaline droplets. Stainless steel is fine on the alkaline side, but chlorides attack 316L — the acid side needs wetted parts in PTFE. A membrane separator is the last liquid barrier before instruments.
Recognise the Symptoms
- Corrosion of fittings, valves or sensors downstream of the gas outlet
- Liquid reaching mass-flow controllers or gas analysers
- Pitting on stainless steel parts on the acid (HCl) side
- Viton seals swell or crack in alkaline service
Root Causes
Electrolyte carry-over as droplets and mist from the cell or separator
316L is attacked by chlorides
not suitable for HCl service
Viton (FKM) is not suited to alkaline media
Sintered PTFE is a depth filter
it removes droplets and much of the mist but is not a fine coalescer
Diagnostic Checklist
- 1Alkaline side: RF-H-132 316L housing (¼″ NPT drain, 100 bar) + RF-TF-25064-003 sintered PTFE element + RF-A-GP130S solid PTFE gasket set
- 2Acid side (HCl): RF-H-132P housing machined from solid PTFE (max. 7 bar, lower at higher temperature) + RF-TF-25064-003
- 3Final liquid barrier: RF-M-GMS105P membrane separator, solid PTFE body, hydrophobic PTFE membrane — route the bypass to a closed collection
- 4Small flows are typical: 20 NL/min at 2 bar(g) is only about 7–8 L/min actual — compact 25 × 64 mm elements are sufficient
- 5No glass bowls for hydrogen, lye or acid; no float drains venting to atmosphere
- 6The customer verifies long-term chemical resistance in the test rig — we give no commitment on service life or efficiency in these electrolytes
Find the right filter for this problem
Enter your operating data and let our tools point you to the right element and housing — or send us your details for a tailored recommendation.
Element Finder
RecommendedIdentify the right filter element for your medium and duty in under 60 seconds — recommended starting point.
Find your elementUse Housing Selector
Select the matching housing — material, pressure rating, connections and drain.
Select a housingRequest a Consultation
Prefer a person? Send your operating data and we will recommend the right configuration.
Send enquiryFurther Reading
Describe Your Situation — We Will Find the Right Solution
Every filtration problem has specific root causes that require specific solutions. Send us your operating conditions and we will provide a tailored recommendation.