Compressor Oil in CNG — Stopping Oil Carryover Before Storage, Dispenser and Vehicle
Lubricated CNG compressors always carry some oil into the gas. Without an effective coalescing stage after the final cooler, the oil travels on as aerosol and droplets — into storage, priority panels, dispensers and vehicle tanks, where it causes sticking valves, leaking nozzles and customer complaints.
Reconocer los síntomas
- Oily film or droplets at dispenser nozzles, breakaway couplings or filling receptacles
- Complaints from fleet operators about oil in vehicle tank valves, regulators or injectors
- Sticking priority valves, check valves or solenoid valves in the station
- Oil collecting in storage vessels and low points and released in slugs
- The existing line filter shows almost no differential pressure — or the element is soaked with oil
Causas
No coalescing stage after the final cooler
separators remove bulk liquid but not fine oil aerosol
Filter installed upstream of the cooler
in hot gas more oil is present as vapour, which passes any mechanical filter and condenses further downstream
Element efficiency too low for oil aerosol
a particulate element or a coarse coalescer lets fine droplets through
Drain not emptied
coalesced oil fills the housing bowl and is re-entrained into the gas
Compressor wear
worn piston rings and valves increase oil carryover over time
Element not changed
a saturated or damaged element loses efficiency; change at 0.7 bar ΔP and at least yearly
Lista de comprobación de diagnóstico
- 1Is there a coalescing filter downstream of the final cooler — and what efficiency is its element rated for?
- 2What is the gas temperature at the filter inlet?
- 3How often is the filter drain emptied, and how much oil is collected?
- 4Is a differential pressure gauge fitted, and when was the element last changed?
- 5Is the compressor lubricated, and has oil consumption increased recently?
- 6Is oil vapour also a problem (odour, residue after the filter)? Then an activated carbon stage may be needed
- 7What operating pressure, flow (Nm³/h) and connection size apply?
Encontrar el filtro adecuado para este problema
Introduzca sus datos de operación — nuestras herramientas le guiarán al elemento y carcasa adecuados. O envíenos sus datos para una recomendación a medida.
Buscador de elementos
RecomendadoEl elemento filtrante adecuado para el medio y la operación en menos de 60 segundos — punto de partida recomendado.
Encontrar elementoUtilizar selección de carcasa
Seleccionar la carcasa adecuada — material, nivel de presión, conexiones y purga.
Seleccionar carcasaSolicitar asesoramiento
¿Prefiere atención personal? Envíe sus datos de operación y le recomendaremos la configuración adecuada.
Enviar solicitudAplicaciones relacionadas
Describa su situación — encontraremos la solución adecuada
Cada problema de filtración tiene causas específicas que requieren soluciones específicas. Envíenos sus condiciones de operación y elaboraremos una recomendación a medida.